GENERAL SPECIFICATIONS

LCD Display : 1999 counts

Display Update Rate : 5 per second nominal

Operating Temperature: -10oC ~ 50oC

Relative Humidity: ≦90%

Altitude: Operating below 2000m

Storage Temperature: -20oC ~ 65oC, ≦80% R.H. (with battery removed)

Temperature Coefficient: Nominal 0.15 x (specified accuracy)/ oC @ (-10oC ~ 18oC or 28oC ~ 50oC), or otherwise specified

Sensing: TRMS sensing for LCD indication; Averaging sensing for LED indication

Measurement Category: CAT III 1000V & CAT IV 600V AC & DC

E.M.C.: Meets EN61326-1:2013

For LCD display only:

Total accuracy = Specified accuracy + 45d @ an RF Field of 3V/m.

Type of Protection: IP65 (Certified by SGS UK)

Pollution Degree: 2

Safety: Meets IEC/EN61010-1 Ed. 3.0, IEC/EN61010-2-033 Ed. 1.0, IEC/EN61243-3:2014 to CAT III 1000V & CAT IV 600V

Transient Protection: 8kV lightning surge (1.2/50 µs)

Overload Protection: 1100VDC & VAC rms

Low Battery: Below approx. 2.6V

Power Supply: 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2

APO Timing:

Resistance and Capacitance functions: Idle for 8 seconds

Other functions: Idle for 16 seconds

Battery Power Consumption (typical):

2.7mA for Power-on ready & DCV

50mA for ACV (with shaker on)

105mA for RCD

40mA for Buzzer on @ Continuity or EF function

55mA for Resistance or Capacitance

Add 30mA for Backlight on

APO Consumption (typical): 12µA

Dimension: L278mm x W57mm x H40mm

Weight: Approx. 235gm

Special Features: EF-Detection; LCD indication, AC-Detection Shaker ; RCD Leakage-Path ; RST Phase Rotation Detection;

Accessories: Batteries, User’s manual, Screw-on stationary red probe and detachable leaded black probe

Electrical Specification

DC & AC Operating Voltage, LED Successive Indication

Voltage

Marking

Typical Turn-ON Threshold

(% of Voltage Marking)

Typical Turn-OFF Threshold

(% of Pre-Voltage Marking)

12V

9.6V (80%)

7V

24V

19.2V (80%)

14V (116%)

50V

40V (80%)

33V (137%)

120V

96V (80%)

67V (134%)

230V

184V (80%)

140V (117%)

400V

320V (80%)

283V (123%)

690V

552V (80%)

490V (122%)

1000V

800V (80%)

760V (110%)

 

DC & AC Operating Voltage, LCD Numeric Indication

RANGE

Auto-Power-ON Threshold

Accuracy

DC 199.9V, 1000V

> +27VDC or < -4.5VDC

1.5%+3d

AC 199.9V, 1000V

> 8VAC

2.5%+4d

AC-Detection Shaker

Shaker Threshold: Between 8V and 15V ac

Audible Continuity

Open Circuit Voltage: 0.7DC typical

Audible Threshold:

Between 500kΩ and 750kΩ

 

Electric Field EF-Detection

Non-Contact EF-Detection values are shown in the following table.

Typical Non-Contact Voltage Range

LCD Bar-Graph Indication

LED Flashing Rate

 

 

#1

15V to 55V

-

#2

30V to 95V

- -

#3

55V to 170V

- - -

#4

Above 120V

- - - -

 

RCD Leakage-Path

RCD Circuit Breakers intended: 30mA/230Vac

Activation inhibited: at <201V or >264V

Activation indication: Flashing RCD-LED accompanied with beep sound

 

RST 3-Phase Rotation Detection

Voltage Range: 165V ~ 1000V

Frequency Range: 45Hz ~ 65Hz

Applications: Intended for Y-connection 3P4W and High-leg Δ-connection 3P3W systems. Not intended for Δ-connection 3P3W systems without an earth-ground neutral.