Kintamosios AC TRUE RMS iki 1500A ir nuolatinės DC iki 2000A srovės matavimo replės CMP-2000

Gamintojas: Sonel
Prekės kodas: WMGBCMP2000
Kaina:
185,00 €be PVM

Universal clamp meter, enabling the maintenance of current measurements up to 2000A, with the diameter of the clamp as 57mm, and bus bar to 70*18mm
The instrument has an electronic overload protection of all functions and ranges.

It provides:

  • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
  • Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling).
  • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
  • Resistance measurement and continuity test:
    - continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
  • Capacitance measurement
  • Temperature measurement (Fahrenheit or Celsius).
  • Frequency measurement.
  • Duty cycle measurement.
  • Diode test.
  • Additionally:
    - safe, insulated measuring clamp,
    - autoranging,
    - „DATA HOLD” function, for holding measured values,
    - backlit LCD,
    - „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
    - „MAX/MIN” function,
    - over range indication,
    - „AUTO-OFF” function after 30min.

Electric security:

  • measurement category: CAT IV 600 V acc. to EN 61010-1,
  • protection class acc. to EN 60529: IP30,

Other technical data:

  • power supply, 9 V battery type 6LR61,
  • display: 6600 counts, backlit LCD,
  • continuity test: threshold 30 Ω,
  • diode test: test current of 0,8 mA , typical open circuit voltage 3,2V DC, typical,
  • low battery indication: BAT displayed,
  • over range indication: ‘OL’ displayed,
  • temperature sensor: type K thermocouple,
  • input impedance: ca.10 MΩ (V DC and V AC),
  • AC bandwidth: 50...500 Hz,
  • auto power OFF: 30 minutes,
  • dimensions: 281 x 108 x 53 mm,
  • weight: 570 g (with battery),
  • accordance with following standards: EN 61010-1, EN 61010-2-032.

Rated operational conditions:

  • able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
  • operating temperature: 0...+50 °C,
  • storage temperature: -20...+60 °C,
  • operating altitude: max 2000m.

 

DC current measurement

Range Resolution Accuracy
0,0...659,9 A 0,1 A ±(2,0% m.v. + 5 digits)
660...2000 A 1 A ±(3,0% m.v. + 5 digits) for 660...1000 A
±(5,0% m.v. + 5 digits) for 1000...2000 A

AC current measurement (TRUE RMS)

Range Resolution Accuracy
0,0...659,9 A 0,1 A ±(2,0% m.v. + 10 digits) for 50...60 Hz
±(3,0% m.v. + 10 digits) for 61...400 Hz
660...1500 A 1 A ±(2,5% m.v. + 10 digits) for 50...60 Hz
i 660...1000 A
±(3,5% m.v. + 10 digits) for 61...400 Hz
and 660...1000 A
±(5,0% m.v. + 10 digits) for 50...400 Hz
and 1000...1500

DC voltage measurement

Range Resolution Accuracy
0,000...6,599 V 0,001 V ±(0,5% m.v. + 2 digits)
6,60...65,99 V 0,01 V
66,0...659,9 V 0,1 V
660...1000 V 1 V

AC voltage measurement (true RMS)
Range Resolution Accuracy
0,000...6,599 V 0,001 V ±(1,5% m.v. + 8 digits)
for 50...500 Hz
6,60...65,99 V 0,01 V
66,0...659,9 V 0,1 V
660...750 V 1

 

Resistance measurement

Range Resolution Accuracy
0,0...659,9 Ω 0,1 Ω ±(1,0% m.v. + 5 digits)
0,660...6,599 kΩ 0,001 kΩ
6,60...65,99 kΩ 0,01 kΩ
66,0...659,9 kΩ 0,1 kΩ
0,660...6,599 MΩ 0,001 MΩ ±(2,0% m.v. + 5 digits)
6,60...66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

Capacitance measurement

Range Resolution Accuracy
0,0...6,599 nF 0,001 nF ±(3,0% m.v. + 30 digits)
6,60...65,99 nF 0,01 nF ±(3,0% m.v. + 10 digits)
66,0...559,9 nF 0,1 nF ±(3,0% m.v. + 30 digits)
6,600...59,999 µF 0,001 µF ±(3,0% m.v. + 10 digits)
66,00...659,99 µF 0,01 µF
660...659,999 µF 0,100 µF
0,660...6,600 mF 0,001 mF

Frequency measurement

Range Resolution Accuracy
10...65,99 Hz 0,01 Hz ±(0,1% m.v. + 5 digits)
66,0...659,9 Hz 0,1 Hz
0,660...6,599 kHz 0,001 kHz
6,60...65,99 kHz 0,01 kHz
66,0...659,9 kHz 0,1 kHz
0,660...1,000 MHz 0,001 MHz

Temperature measurement

Range Resolution Accuracy
-20...0°C 1°C ±(2,0% m.v. + 3°C)
0...399°C ±(1,0% m.v. + 2°C)
400...1000°C ±(2,0% m.v. + 3°C)
-4...31°F 1°F ±(2,0% m.v. + 6°F)
32..749°F ±(1,0% m.v. + 4°F)
750...1832°F ±(2,0% m.v. + 6°F)

Duty cycle measurement
ange Resolution Accuracy
5...95% 0,1% ±(2,0% m.v. + 10 digits)

„m.v.”- measured value

Daugiau informacijos